Dimension :
140 x 150 x 86 mm |
|
|
> |
PFC :
Passive (Optional) |
|
|
> |
Related Information : |
|
|
|
|
Features:
|
- Passive PFC(Power
Factor Correction) circuit at 230 Vac
- High efficiency
- Low ripple &Noise
- Output over voltage
protection
- Short circuit
protection on all output
- Reset table power
shut down
|
Specifications
|
INPUT SPECIFICATIONS
|
Input voltage: |
115/230 VAC |
Input frequency: |
47 Hz to 63 Hz |
Input current: |
10 amps maximum / 115
Vrms, 60Hz; |
|
5 amps maximum / 230
Vrms, 50Hz. |
|
OUTPUT SPECIFICATIONS
|
Over-voltage protection: |
+5V: 6.5V (maximum); |
|
+3.3V: 4.6V (maximum); |
|
+12V:15.5V (maximum). |
Over-current protection: |
+3.3V:81A maximum; |
|
+5V:65A maximum; |
|
+12V:30A maximum. |
Remote ON/OFF control: |
The power supply shall accept a logic collector
level which |
|
will disable / enable all output voltage (excluding
+5V standby). |
Power good signal: |
115/230V (full load) : 100 - 500 ms |
|
GENERAL
SPECIFICATIONS
|
Efficiency: |
65% min. |
Hold-up
time: |
17.0 ms minimum: at
115V / 60 Hz; |
|
17.0 ms minimum: at
230V / 50 Hz. |
|
ENVIRONMENTAL SPECIFICATIONS
|
Operating conditions: |
ambient temperature
0°C~50°C |
Storage
and shipping conditions: |
ambient temperature
-20°C~+65°C |
Dielectric withstand: |
input / output 1800 VAC
for 1 second, |
|
input to frame ground
1800VAC for 1 second |
|
|
Output
Output Voltage |
Min. load |
Max. load |
Load Reg. |
Ripple & Noise |
+5Vsb |
0.0A |
2.0A |
±5% |
50mV P-P |
-5V |
0.0A |
0.3A |
±10% |
100mV P-P |
-12V |
0.0A |
0.8A |
±10% |
120mV P-P |
+12V |
0.2A |
16.0A |
±5% |
120mV P-P |
+5V |
1.0A |
30/25.5A |
±5% |
50mV P-P |
+3.3V |
0.3A |
21.2/28.0A |
±5% |
50mV P-P |
|
|
|
|