MX3-5750P (750W)
|
> Output wattage:
750W > Best Solution for:
Server,Workstation,IPC
> Dimension:
265 x 150 x 84 mm
> AC Input Spec....
VOLTAGE: 100-240VAC FULL RANGE
FREQUENCY: 50-60HZ
INPUT CURRENT:5A(RMS)FOR 230VAC
13A(RMS)FOR 115VAC
INRUSH CURRENT:110A MAX. FOR 115 VAC PER MODULE
150A MAX. FOR 230 VAC PER MODULE |
|
Features:
|
- TEMPERATURE RANGE:OPERATING 0°C-40°C,STORAGE
-20°C-70°C
- HUMIDITY:OPERATING:20%-95%,
NON-OPERATING:10%-95%
- REMARKS:85% IS NORMAL CONDITION AND 95% IS
WITH SPECIAL COATING PROCESS
- HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC
INPUT VOLTAGE
- DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR
1 minute INPUT TO FRAME GROUND 1500 VAC FOR 1
minute
- EFFICIENCY:65% TYPICAL,AT FULL LOAD
- POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF
DELAY 1mS
- OVERLOAD PROTECTION:110-160% MAX
- OVER VOLTAGE PROTECTION:+5V_5.7V-6.7V,+3.3V_3.7V-4.7V,
+12V_13.0V-15.0V
- SHORT CIRCUIT: 5V,12V,3.3V, AUTO-RECOVERED:
5VSB,-12V
- EMI : FCC CLASS B , CISPR 22 CLASS B
- SAFETY:UL 60950, CB IEC60950, TUV EN60950
- REMOTE ON / OFF CONTROL
- FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
- MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
- 2 +1, HOT-SWAPPABLE / HOT PLUGGABLE REDUNDANCY
FUNCTION
- N +1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V
CHANNEL
- REMOTE SENSING DESIGN
- ISOLATION: BUILT-IN THE POWER MODULE
- COOLING: THREE 40mm DC FANS (ONE IN EACH
MODULE)
|
|
DC Output Spec.... |
Output Voltage
|
Output Current Min.
|
Output Current Max.
|
Output Current Peak
|
Regulation Load
|
Regulation Line
|
Output Ripple & Noise Max.[P-P] |
2 |
2 |
52.00 |
|
±5% |
±1% |
50mV |
+12V |
3 |
56 |
|
±5% |
±1% |
120mV |
-12V |
0,1 |
1.00 |
|
±5% |
±1% |
150mV |
+3.3V |
1 |
40.00 |
|
±5% |
±1% |
50mV |
+5VSB |
0,1 |
3.5 |
|
±5% |
±1% |
50mV |
|
TOTAL CURRENT OF +5V AND +3.3V NOT EXCEED 70A |
|
|
|
|
|
|